Product Overview
- 5 ports accepting 5v - 47v with onboard power management and able to accept individual voltages
- Power ports are banked (4 + 4 + 4 + 4 + 1)
- 17 Ports handling up to 750 pixels per port at 40fps
- 17 fused connectors which combined with the included 7.5 amp fuses allows for full pixel runs at 100%
- DDP, Artnet, E1.31 & sACN compatible
- 3 Programmable Turniputs ports (Can use the FPP API to start / stop a sequence and full lamp control)
- No separate FPP or FPP license required
- Fuse indicator lights for easy troubleshooting
- Dual Wired 10/100 ethernet
- Built in test modes
- Direct xLights integration for controller config push (2024.10 and later)
Visit https://www.baldrickboard.com/docs/baldrick17/introduction/ for more information.